VERO 700 VE
 |
(1) supply
(2) exhaust |
|
VERO |
700VE |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Heater |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
|
- power consumption |
[kW] |
2,0 |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,280/1,22 |
|
|
- fan speed |
[min-1] |
2050 |
|
- supply |
- power/current |
[kW/A] |
0,280/1,22 |
|
|
- fan speed |
[min-1] |
2050 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
2,57/11,21 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
104,0 |
VERO 700 VW
 |
(1) supply
(2) exhaust |
|
VERO |
700VW |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Water heater |
- power |
[kW] |
NVS 250 |
|
|
- water Tin/Tout |
[°C] |
|
|
- water pressure drop |
[kPa] |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,280/1,22 |
|
|
- fan speed |
[min-1] |
2050 |
|
- supply |
- power/current |
[kW/A] |
0,280/1,22 |
|
|
- fan speed |
[min-1] |
2050 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
0,57/2,52 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
104,0 |
Air flow temperature range from -20°C to +40°C
Designed for operation indoors only.
Thermal efficiency of VERO 700VE was measured at 700m3/h, at temperature range from -20°C to +20°C.
Thermal efficiency of VERO 700VW was measured at 700m3/h, at temperature range from -20°C to +20°C.
VERO 700 HE
 |
(1) supply
(2) exhaust |
|
VERO |
700HE |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/250 |
|
Heater |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
|
- power consumption |
[kW] |
2,0 |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,300/1,31 |
|
|
- fan speed |
[min-1] |
2050 |
|
- supply |
- power/current |
[kW/A] |
0,300/1,31 |
|
|
- fan speed |
[min-1] |
2050 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
2,61/11,39 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
104,0 |
VERO 700 HW
 |
(1) supply
(2) exhaust |
|
VERO |
700HW |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/250 |
|
Water heater |
- power |
[kW] |
NVS 250 |
|
|
- water Tin/Tout |
[°C] |
|
|
- water pressure drop |
[kPa] |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,300/1,31 |
|
|
- fan speed |
[min-1] |
2050 |
|
- supply |
- power/current |
[kW/A] |
0,300/1,31 |
|
|
- fan speed |
[min-1] |
2050 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
0,61/2,70 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
96,0 |
Air flow temperature range from -20°C to +40°C
Designed for operation indoors only.
Thermal efficiency of VERO 700HE was measured at 700m3/h, at temperature range from -20°C to +20°C.
Thermal efficiency of VERO 700HW was measured at 700m3/h, at temperature range from -20°C to +20°C.
VERO 700VE, VERO 700VW
 |
|
L |
W |
H |
Ø D |
H1 |
F |
|
653 mm |
1000 mm |
980 mm |
250 mm |
40 mm |
40 mm |
|
VERO 700HE, VERO 700HW
 |
|
L |
W |
H |
Ø D |
H1 |
F |
|
1100 mm |
653 mm |
700 mm |
250 mm |
40 mm |
40 mm |
|
VERO 700VE
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor |
VERO 700VW
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
NVS - optionally supplied water heater
IV- exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor
M1 - optionally supplied mixing valve and motor |
VERO 700HE
A - fresh air
B - supply air
C - extract air
D - exhaust air
* - supplied with integrated automatic
controll (VERO 400HE-1500HE). |
|
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor *
TL - air temperature sensor * |
VERO 700HW
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
NVS - optionally supplied water heater
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor
M1 - optionally supplied mixing valve and motor |
|
|
 |
|
 |
|
|