VERO 700 VE EC
 |
(1) supply
(2) exhaust |
|
VERO |
700VE EC |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Heater |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
|
- power consumption |
[kW] |
2,0 |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,177/1,20 |
|
|
- fan speed |
[min-1] |
1740 |
|
- supply |
- power/current |
[kW/A] |
0,177/1,20 |
|
|
- fan speed |
[min-1] |
1740 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
2,36/11,17 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
104,0 |
VERO 700 VW EC
 |
(1) supply
(2) exhaust |
|
VERO |
700VW EC |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Water heater |
- power |
[kW] |
NVS 250 |
|
|
- water Tin/Tout |
[°C] |
|
|
- water pressure drop |
[kPa] |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,177/1,20 |
|
|
- fan speed |
[min-1] |
1740 |
|
- supply |
- power/current |
[kW/A] |
0,177/1,20 |
|
|
- fan speed |
[min-1] |
1740 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
0,36/2,48 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
104,0 |
Air flow temperature range from -20°C to +40°C
Designed for operation indoors only.
Thermal efficiency of VERO 700VE EC was measured at 700m3/h, at temperature range from -20°C to +20°C.
Thermal efficiency of VERO 700VW EC was measured at 700m3/h, at temperature range from -20°C to +20°C.
VERO 700 HE EC
 |
(1) supply
(2) exhaust |
|
VERO |
700HE EC |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Heater |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
|
- power consumption |
[kW] |
2,0 |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,173/1,30 |
|
|
- fan speed |
[min-1] |
1740 |
|
- supply |
- power/current |
[kW/A] |
0,173/1,29 |
|
|
- fan speed |
[min-1] |
1740 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
2,35/11,36 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
96,0 |
VERO 700 HW EC
 |
(1) supply
(2) exhaust |
|
VERO |
700HW EC |
|
Efficiency/compression |
[m3/h]/[Pa] |
500/180 |
|
Water heater |
- power |
[kW] |
NVS 250 |
|
|
- water Tin/Tout |
[°C] |
|
|
- water pressure drop |
[kPa] |
|
Fans |
- phase/voltage |
[50Hz/VAC] |
~1, 230 |
|
- exhaust |
- power/current |
[kW/A] |
0,173/1,30 |
|
|
- fan speed |
[min-1] |
1740 |
|
- supply |
- power/current |
[kW/A] |
0,173/1,29 |
|
|
- fan speed |
[min-1] |
1740 |
|
Motor protection class |
|
IP-44 |
|
Thermal efficiency |
|
74% |
|
Max power consumption |
[kW/A] |
0,35/2,67 |
|
Automatic control |
|
integrated |
|
Filter class - exhaust |
|
EU5 |
|
Filter class - supply |
|
EU5 |
|
Thermal insulation |
[mm] |
50 |
|
Weight |
[kg] |
96,0 |
Air flow temperature range from -20°C to +40°C
Designed for operation indoors only.
Thermal efficiency of VERO 700HE EC was measured at 700m3/h, at temperature range from -20°C to +20°C.
Thermal efficiency of VERO 700HW EC was measured at 700m3/h, at temperature range from -20°C to +20°C.
VERO 400VE EC, VERO 400VW EC
 |
|
L |
W |
H |
Ø D |
H1 |
F |
|
653 mm |
1000 mm |
980 mm |
250 mm |
40 mm |
40 mm |
|
VERO 400HE EC, VERO 400HW EC
 |
|
L |
W |
H |
Ø D |
H1 |
F |
|
1100 mm |
653 mm |
700 mm |
250 mm |
40 mm |
40 mm |
|
VERO 700VE EC
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor |
VERO 700VW EC
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
NVS - optionally supplied water heater
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor
M1 - optionally supplied mixing valve and motor |
VERO 700HE EC
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
KE - electrical heater
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor |
VERO 700HW EC
A - fresh air
B - supply air
C - extract air
D - exhaust air |
|
NVS - optionally supplied water heater
IV - exhaust air fan
PV - supplied air fan
RR - rotary heat exchanger
R - rotor motor
PF - fresh air filter (class EU5)
IF - extract air filter (class EU5)
TJ - air temperature sensor
TL - air temperature sensor
M1 - optionally supplied mixing valve and motor |
|
|
 |
|
 |
|
|